Molecular sieve type commonly used pressurized oxygen adsorption and desorption pressure (HP) method, carried out by two adsorption towers were the same cycle, in order to achieve continuous supply. System-wide automatic control by the SCM.
Molecular sieve type oxygen free home-based molecular sieve oxygen concentrator, medical zeolite gas machine
Molecular sieve type oxygen flow to the working principle of the two towers. After feed air pressurized by the compressor, through the air pretreatment means to remove oil, dust and other solid impurities and water, and cooled to room temperature, treated by the compressed air through the intake valve into the adsorber containing a molecular sieve, the air nitrogen, carbon dioxide is adsorbed effluent gas is the high purity oxygen, Tada when adsorbed to a certain saturation, the intake valve closed, the flush valve opens, the adsorption tower into the rinse stage, after the flush valve is closed, the valve opens desorption into the desorption regeneration phase, so that a complete cycle.
The main technical parameters of the molecular sieve oxysiv sieve type oxygen machine
1, the device normal operating conditions Ambient temperature: 5 ℃ ~ 40 ℃
Power supply voltage: 220V ± 22V air compressor host Oxygen, oxygen compressor 380V ± 38V
Power frequency: 50Hz ± 1Hz
Power: 37KW
Relative humidity: ≤80%
Atmospheric pressure: 86Kpa ~ 106Kpa
Host size L × W × H (without air compressor): 3.5 m × 1.8 米 × 2.7 米
2, the physical and chemical indicators of oxygen production equipment manufactured product oxygen 20m3 / h
Oxygen concentration: ≥ 90% (V / V)
Moisture content: ≤0.07g / m3
Carbon dioxide content: ≤0.01% (V / V)
Carbon monoxide content should be consistent with YY / T0298
Gaseous acid and alkali content should be consistent with YY / T0298
Ozone and other gaseous oxide content should be consistent with YY / T0298
Solids particle size: ≤10μm solids content: ≤0.5mg / m3
Edit this paragraph principle characteristic molecular sieve oxygen plant advanced: the use of zeolite, pressure swing adsorption (PSA) will air in oxygen and nitrogen separation, filter out harmful substances in the air, in order to gain compliance with standards of high purity medical oxygen oxygen. Oxygen and low cost: the air as raw material, without any additives, no residue and pollution emissions, low power consumption. Easy to use: plug the production of oxygen, simple operation, stable oxygen concentration, oxygen flow rate is adjustable, as used with the system, 24-hour continuous oxygen. Safe and reliable: Full pneumatic control procedures are low pressure system, stable performance, low noise.